Size Range
Material
Finish
Service
Maximum Temperature
Complies With
Features
Ordering |
: 1" - 8"
: Mild Steel
: Hot-Dip Galvanized
: Recommended for suspension of non-insulated,
stationary pipe line.
: 650F
: Federal Specificarion WW-H-171E (Type 10) and
Manufacturers. Standardization Society SP-69
(Type 10)
: Permits installation before or after pipe is in place.
: Provides economical installation.
: Specify pipe size, figure number, name. |
|
 |
Size Range
Material
Finish
Service
Maximum Temperature
Complies With
Features
Ordering |
: 1" - 8"
: Mild Steel
: Hot-Dip Galvanized
: Recommended for suspension of non-insulated
pipe lines or conduit.
: 450F
: Federal Specificarion WW-H-171E (Type 11) and
Manufacturers. Standardization Society SP-69
(Type 11)
: Permits installation before or after pipe is in place.
: Provides economical installation.
: Specify pipe size, figure number, name. |
|
 |
Size Range
Material
Finish
Service
Maximum Temperature
Complies With
Features
Ordering |
: 2" - 8"
: Mild Steel
: Hot-Dip Galvanized
: Recommended for suspension of non-insulated
pipe lines.
: 450F
: Federal Specificarion WW-H-171E (Type 25) and
Manufacturers. Standardization Society SP-69
(Type 12)
: Rapid installation assured by hinged design and
single closure screw.
: When used with nipple this clamp is particularly
adaptive for use on
refrigeration or compressor
piping subject to vibration.
: Interior design provides firm grip on pipe.
: Inside of ring tapered to prevent entrapme of
condensed moisture.
: Specify pipe size, figure number, name. |
|
 |
Size Range
Material
Finish
Service
Maximum Temperature
Complies With
Installation
Features
Ordering |
: 3/4" - 10"
: Mild Steel
: Hot-Dip Galvanized
: Recommended for suspension of cold pipe lines or
hot lines where little or no insulation is required.
pipe lines or conduit.
: 750F
: Federal Specificarion WW-H-171E (Type 4) and
Manufacturers. Standardization Society SP-69
(Type 4)
: Normally used with bolt and nut or hanger rod
: Load rating meet ANSI code requirements and
are substantiated by laboratory test.
: Clamps tightly to pipe
: Wide range of sizes
: Specify pipe size, figure number, name. |
|
 |
Size Range
Material
Finish
Maximum Temperature
Complies With
Ordering |
: 1" - 8"
: Mild Steel
: Hot-Dip Galvanized
: 650F
: Federal Specificarion WW-H-171E (Type 26) and
Manufacturers. Standardization Society SP-69
(Type 26)
: Specify pipe size, figure number, name. |
|
 |
Size Range
Material
Finish
Service
Maximum Temperature
Complies With
Installation
Adjustment
Features
Ordering |
: 3/4" - 12"
: Mild Steel
: Hot-Dip Galvanized
: Recommended for suspension of non-insulated,
stationary pipe lines.
: 650F
: Federal Specificarion WW-H-171E (Type 1) and
SP- 69 (Type 1)
: Hanger load nut above clevis must be tightened
securely to assure proper hanger performance.
: Vertical adjustment without removing pipe may be
made from 1 1/8" to 5", varying with the size of
clevis. Tighten upper nut after adjustment.
: Design has yoke on outside of lower U-strap so yoke
cannot slide toward center of bolt is minimized.
: Sizes 2 1/2" and up have rod and two nuts instead
of bolt and nut; thread length
on clevis rod is such that the
threads locks the nuts in place and threads are
not in shear plane.
: Specify pipe size, figure number, name. |
|